Fiber Network Verifies Independent Optical Clocks Below 10⁻¹⁷

A two-month, four-country fiber campaign compared seven clocks and measured frequency ratios with uncertainties from 7.7×10⁻¹⁸ to 6.1×10⁻¹⁷.

Editorial Desk·September 2, 2026·4 min readstrong

Underlying Paper

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

arXiv:2604.27963Submitted: Sep 2, 2026v2

Optical clocks now estimate fractional-frequency uncertainties at, and sometimes below, 101810^{-18}, but their agreement across independently built systems remains a practical test for a future optical definition of the second. The authors report a 2023 campaign that connected seven clocks at INRIM, LNE-OP, NPL, and PTB through European optical-fiber links. Its central result is an international comparison of the NPL and PTB 171Yb+(E3)^{171}\mathrm{Yb}^+(\mathrm{E3}) ion clocks with 7.7×10187.7\times10^{-18} uncertainty: the first such check of independently developed optical clocks below one part in 101710^{17}.

Core Contribution

The contribution is a network-scale consistency measurement rather than a new clock architecture. By operating multiple species and clock types in one linked campaign, the study turns pairwise frequency-ratio measurements into a test of whether national standards agree at the level needed for international metrology. The campaign also supplies new direct ratios involving the 199Hg^{199}\mathrm{Hg} lattice clock at LNE-OP, whose earlier comparison history included discrepancies without a definitive experimental cause.

That scope matters because a prospective redefinition of the SI second cannot rest only on uncertainty budgets reported by individual laboratories. It needs comparisons that expose mismatches between independent realizations. The paper's value is therefore both the smallest reported cross-border uncertainty and a more realistic account of where the network still finds tension.

Technical Approach

The campaign ran for two months in early 2023, using stabilized optical-fiber links to compare clocks in four European national metrology institutes. The network included 171Yb+(E3)^{171}\mathrm{Yb}^+(\mathrm{E3}) ion clocks at NPL and PTB, a 199Hg^{199}\mathrm{Hg} clock at LNE-OP, and 171Yb^{171}\mathrm{Yb} and 87Sr^{87}\mathrm{Sr} lattice-clock measurements involving the participating institutes. Fiber transfer is intended to make the link contribution negligible relative to the clock comparisons, allowing the measured ratios to probe the clocks rather than satellite-transfer noise.

The paper expresses each ratio as a fractional offset, y=R/R01y=R/R_0-1, relative to a reference ratio from a least-squares adjustment of standard frequencies. Daily averages combine statistical and systematic uncertainty in quadrature. The reported uncertainty bands account for excess scatter by inflating the statistical component with the Birge ratio when it exceeds one; the Allan-deviation analysis tests the assumed white-frequency-noise scaling with averaging time. Correlations between ratio measurements are also evaluated, an important detail when several ratios share clocks and links.

Results and Analysis

The strongest evidence comes from the NPL–PTB 171Yb+(E3)^{171}\mathrm{Yb}^+(\mathrm{E3}) comparison, which agrees within 7.7×10187.7\times10^{-18}. Across the campaign, reported ratio uncertainties span 7.7×10187.7\times10^{-18} to 6.1×10176.1\times10^{-17}. These are direct experimental measurements over a shared campaign, not extrapolations from separate clock evaluations.

Figure 3 presents the daily ratio offsets, their statistical and total error bars, and the measurement duration and Birge ratio for each comparison. This presentation makes a useful distinction: the nominal precision of a daily point is not automatically the uncertainty of the campaign average when repeatability shows extra scatter.

Figure 3. Measured daily average frequency ratios between different clocks in this campaign. Each optical frequency ratio is reported as a fractional offset, y = R/R_0 - 1, where R is the measured value and R_0 is the corresponding reference frequency ratio obtained from a least-squares adjustment of standard frequencies (Appendix B of Ref.~Margolis2024). The blue error bars represent the total uncertainties, evaluated as the sum in quadrature of statistical and systematic contributions. For panels involving PTB-Sr3, the systematic uncertainty of PTB-Sr3 is not included. The orange error bars represent the statistical uncertainties of each point. The box in each plot reports the Birge ratio B, the number of degrees of freedom n and the total measurement time T. The blue regions show the average value with the total evaluated uncertainty, with the statistical contribution inflated by the Birge ratio.

For 199Hg^{199}\mathrm{Hg}, the LNE-OP-to-NPL 199Hg/87Sr^{199}\mathrm{Hg}/^{87}\mathrm{Sr} ratio is consistent within 2σ2\sigma with two earlier measurements and with the reference ratio. The authors attribute greater confidence relative to earlier campaigns to a longer campaign and revised treatment of systematic effects including quadratic Zeeman, cold-collision, and background-gas collision shifts. The result strengthens the mercury clock's comparison record, but does not prove that every historical discrepancy has been explained.

The paper is appropriately less tidy for 171Yb/87Sr^{171}\mathrm{Yb}/^{87}\mathrm{Sr}. One INRIM–NPL result disagrees by 4σ4\sigma with a 2018 NIST–JILA measurement and an earlier ROCIT 2022 result, while agreeing with RIKEN measurements and a more recent BACON result. The authors report no identified experimental error or overlooked systematic effect. That unresolved conflict is not peripheral: it is evidence that network comparisons are still needed before ratio data can be treated as fully settled inputs to a redefined second.

Limits in Practice

This is a strong campaign measurement, but it covers seven clocks, four institutes, and a two-month window rather than a global, continuous ensemble. The uncertain source of several ratio inconsistencies also constrains the interpretation. The paper establishes that fiber-linked international verification can reach the low-101810^{-18} range for one key pair; it does not establish universal agreement among optical-clock species or laboratories.

Evidence Box

strong

Key Claims

  • Fiber-linked comparisons can verify independent optical clocks below 10⁻¹⁷
  • The campaign improves direct ratio measurements involving the ¹⁹⁹Hg clock
  • Network comparisons can reveal inconsistencies relevant to redefining the second

Key Results

  • 7.7×10⁻¹⁸ uncertainty for the NPL–PTB ¹⁷¹Yb⁺(E3) comparison
  • 7.7×10⁻¹⁸ to 6.1×10⁻¹⁷ uncertainty range across measured ratios
  • SYRTE-Hg/NPL-Sr consistent within 2σ of two earlier ¹⁹⁹Hg/⁸⁷Sr measurements
  • One ¹⁷¹Yb/⁸⁷Sr result differs by 4σ from 2018 and ROCIT 2022 measurements

Limitations & Caveats

  • Seven clocks at four European institutes over a two-month campaign
  • No identified cause for several frequency-ratio inconsistencies
  • Agreement below 10⁻¹⁷ demonstrated for one international clock pair
  • Results remain tied to reference ratios from a least-squares adjustment